Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Zookeys ; 1198: 295-340, 2024.
Article in English | MEDLINE | ID: mdl-38708380

ABSTRACT

The current study presents an annotated checklist of the land snail species in the vicinity of the limestone hill of Gua (= cave) Rumbang, an outcrop located at the district of Padawan, Sarawak, Malaysian Borneo. The sampling was conducted at the surrounding areas and near the cave's entrance. A total of 62 species, involving 19 families and 38 genera, were recorded. Comparison with previous surveys made in the Bau limestone hills revealed similarities with respect to the species-rich families Diplommatinidae and Cyclophoridae, and the genera Kaliella and Diplommatina, highlighting the regional consistency of the land snail diversity of the Bau-Padawan-Serian cluster. Possibly because of its smaller size, Gua Rumbang is home to two endemic species, while there are eight endemic species in the Bau limestone karsts. This suggests a potential for a significant species diversity within the areas of the limestone ranges that remain to be explored. Nonetheless, the occurrence of endemic species in Gua Rumbang highlights the need to conserve certain areas within the Padawan limestone range since hitherto no protected areas have been proposed in this region. In this checklist, a new species for science is also described, namely, Diplommatinarumbangensissp. nov.

2.
Biodivers Data J ; 12: e115556, 2024.
Article in English | MEDLINE | ID: mdl-38405381

ABSTRACT

Background: The present study provides a checklist of land snails collected from Batu Kudik, a small and isolated limestone outcrop in Simunjan, Sarawak. A total of 24 species of land snails, representing 18 genera and 14 families were recorded, including one newly-described subspecies. The most species-rich of the families in Batu Kudik are Diplommatinidae (17%) and Chronidae (17%) with four recorded species from each of the families. Based on our analysis, Plectostomawallaceikudikense subsp. nov., Opisthostomajavanica and Georissapyrrhoderma were identified as the most abundant land snails at this isolated outcrop, whereas Diplommatinaonyx and Everettiaminuta were recorded as the least abundant. All of the land snails at Batu Kudik were exclusively found sheltered between limestone boulders, underscoring the critical role of this outcrop as their refuge for survival. Consequently, conserving this biodiversity-rich limestone area becomes paramount to prevent the local extinction of these land snail species and possibly other organisms that depend on the unique attributes of the limestone for their survival. We also provide detailed descriptions of Plectostomawallaceikudikense, a new subspecies of the genus Plectostoma which is endemic to Batu Kudik. New information: A description of a new subspecies Plectostomawallaceikudikense subsp. nov.

3.
J Cardiovasc Electrophysiol ; 35(4): 727-736, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38351331

ABSTRACT

INTRODUCTION: Clinical outcomes of long-term ventricular septal pacing (VSP) without His-Purkinje capture remain unknown. This study evaluated the differences in clinical outcomes between conduction system pacing (CSP), VSP, and right ventricular pacing (RVP). METHODS: Consecutive patients with bradycardia indicated for pacing from 2016 to 2022 were prospectively followed for the clinical endpoints of heart failure (HF)-hospitalizations and all-cause mortality at 2 years. VSP was defined as septal pacing due to unsuccessful CSP implant or successful CSP followed by loss of His-Purkinje capture within 90 days. RESULTS: Among 1016 patients (age 73.9 ± 11.2 years, 47% female, 48% atrioventricular block), 612 received RVP, 335 received CSP and 69 received VSP. Paced QRS duration was similar between VSP and RVP, but both significantly longer than CSP (p < .05). HF-hospitalizations occurred in 130 (13%) patients (CSP 7% vs. RVP 16% vs. VSP 13%, p = .001), and all-cause mortality in 143 (14%) patients (CSP 7% vs. RVP 19% vs. VSP 9%, p < .001). The association of pacing modality with clinical events was limited to those with ventricular pacing (Vp) > 20% (pinteraction < .05). Adjusting for clinical risk factors among patients with Vp > 20%, VSP (adjusted hazard ratio [AHR]: 4.74, 95% confidence interval [CI]: 1.57-14.36) and RVP (AHR: 3.08, 95% CI: 1.44-6.60) were associated with increased hazard of HF-hospitalizations, and RVP (2.52, 95% CI: 1.19-5.35) with increased mortality, compared to CSP. Clinical endpoints did not differ between VSP and RVP with Vp > 20%, or amongst groups with Vp < 20%. CONCLUSION: Conduction system capture is associated with improved clinical outcomes. CSP should be preferred over VSP or RVP during pacing for bradycardia.


Subject(s)
Heart Failure , Pacemaker, Artificial , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Bradycardia/diagnosis , Bradycardia/therapy , Bradycardia/etiology , Prognosis , Cardiac Pacing, Artificial/adverse effects , Cardiac Conduction System Disease , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/etiology , Bundle of His , Electrocardiography , Treatment Outcome
4.
Nanotechnology ; 35(16)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38154139

ABSTRACT

Preparing Cd3As2, which is a three-dimensional (3D) Dirac semimetal in certain crystal orientation, on Si is highly desirable as such a sample may well be fully compatible with existing Si CMOS technology. However, there is a dearth of such a study regarding Cd3As2films grown on Si showing the chiral anomaly. Here,for the first time, we report the novel preparation and fabrication technique of a Cd3As2(112) film on a Si (111) substrate with a ZnTe (111) buffer layer which explicitly shows the chiral anomaly with a nontrivial Berry's phase ofπ. Despite the Hall carrier density (n3D≈9.42×1017cm-3) of our Cd3As2film, which is almost beyond the limit for the portents of a 3D Dirac semimetal to emerge, we observe large linear magnetoresistance in a perpendicular magnetic field and negative magnetoresistance in a parallel magnetic field. These results clearly demonstrate the chiral magnetic effect and 3D Dirac semimetallic behavior in our silicon-based Cd3As2film. Our tailoring growth of Cd3As2on a conventional substrate such as Si keeps the sample quality, while also achieving a low carrier concentration.

5.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1393-1403, 2023 08.
Article in English | MEDLINE | ID: mdl-37558292

ABSTRACT

BACKGROUND: Left bundle branch (LBBP) and His-bundle pacing (HBP) provide physiological ventricular activation. OBJECTIVES: This study investigated differences in feasibility, device performance, and clinical outcomes between LBBP and HBP. METHODS: Consecutive patients with LBBP and HBP from 2018 to 2021 in 2 centers were prospectively studied. The primary endpoint was optimal device performance during follow-up, defined as the presence of pacing thresholds <2.5 V, R-wave amplitude ≥5 V, and absence of conduction system pacing (CSP)-related complications. The secondary endpoint was the composite of heart failure hospitalizations or all-cause mortality. RESULTS: Among 338 patients, 282 underwent successful CSP (119 HBP, 163 LBBP). Success rates, CSP-related complications, and need for reoperations did not differ between LBBP and HBP (P > 0.05). Pacing thresholds were lower, whereas R-wave amplitudes and lead impedance were higher in LBBP (P < 0.05). The primary endpoint was more frequent in LBBP than HBP (79% vs 34%; P < 0.001), with LBBP independently associated with 9-fold increased odds of optimal device performance (adjusted OR: 9.31; 95% CI: 5.14-16.86). LBBP was less likely to have increased pacing thresholds by >1 V (1% vs 19% HBP, P < 0.001). The secondary outcome was less frequent in LBBP than HBP (9% vs 24%, P = 0.001), with LBBP trending towards higher event-free survival (HR: 0.62; 95% CI: 0.31-1.23). The secondary outcome was independent of pacing burden or pacing indication. CONCLUSIONS: Despite similar feasibility and safety profiles, LBBP confers additional benefits in pacing performance and reliability, shows trends towards improved survival compared to HBP, and should be the preferred first-line CSP modality of choice.


Subject(s)
Bundle of His , Cardiac Pacing, Artificial , Humans , Reproducibility of Results , Electrocardiography , Heart Conduction System , Cardiac Conduction System Disease
6.
J Cardiovasc Electrophysiol ; 34(4): 976-983, 2023 04.
Article in English | MEDLINE | ID: mdl-36906813

ABSTRACT

INTRODUCTION: The benefits of cardiac resynchronization therapy (CRT) with biventricular pacing (BiV) is significantly lower when applied to heart failure (HF) patients with non-left bundle branch block (LBBB) conduction delay. We investigated clinical outcomes of conduction system pacing (CSP) for CRT in non-LBBB HF. METHODS: Consecutive HF patients with non-LBBB conduction delay undergoing CSP were propensity matched for age, sex, HF-etiology, and atrial fibrillation (AF) in a 1:1 ratio to BiV from a prospective registry of CRT recipients. Echocardiographic response was defined as an increase in left ventricular ejection fraction (LVEF) by ≥10%. The primary outcome was the composite of HF-hospitalizations or all-cause mortality. RESULTS: A total of 96 patients were recruited (mean age 70 ± 11years, 22% female, 68% ischemic HF and 49% AF). Significant reductions in QRS duration and LV dimensions were seen only after CSP, while LVEF improved significantly in both groups (p < 0.05). Echocardiographic response occurred more frequently in CSP than BiV (51% vs. 21%, p < 0.01), with CSP independently associated with four-fold increased odds (adjusted odds ratio 4.08, 95% confidence interval [CI] 1.34-12.41). The primary outcome occurred more frequently in BiV than CSP (69% vs. 27%, p < 0.001), with CSP independently associated with 58% risk reduction (adjusted hazard ratio [AHR] 0.42, 95% CI 0.21-0.84, p = 0.01), driven by reduced all-cause mortality (AHR 0.22, 95% CI 0.07-0.68, p < 0.01), and a trend toward reduced HF-hospitalization (AHR 0.51, 95% CI 0.21-1.21, p = 0.12). CONCLUSIONS: CSP provided greater electrical synchrony, reverse remodeling, improved cardiac function and survival compared to BiV in non-LBBB, and may be the preferred CRT strategy for non-LBBB HF.


Subject(s)
Atrial Fibrillation , Cardiac Resynchronization Therapy , Heart Failure , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Cardiac Resynchronization Therapy/adverse effects , Stroke Volume , Bundle-Branch Block , Ventricular Function, Left/physiology , Treatment Outcome , Heart Failure/therapy , Atrial Fibrillation/therapy
7.
JACC Clin Electrophysiol ; 9(7 Pt 1): 992-1001, 2023 07.
Article in English | MEDLINE | ID: mdl-36752453

ABSTRACT

BACKGROUND: Conduction system pacing (CSP) provides more physiological ventricular activation than right ventricular pacing (RVP). OBJECTIVES: This study evaluated the differences in clinical outcomes in patients receiving CSP and RVP. METHODS: Consecutive patients with pacemakers implanted for bradycardia from 2016 to 2021 in 2 centers were prospectively followed for the primary composite outcome of heart failure (HF) hospitalizations, upgrade to biventricular pacing, or all-cause mortality, stratified by ventricular pacing burden (Vp) . RESULTS: Among 860 patients (mean age 74 ± 11 years, 48% female, 48% atrioventricular block), 628 received RVP and 231 received CSP (95 His-bundle pacing, 136 left bundle branch pacing). The primary outcome occurred in 217 (25%) patients, more commonly in patients with RVP than CSP (30% vs 13%, P < 0.001). In multivariable analyses, CSP was independently associated with 47% reduction of the primary outcome (adjusted hazard ratio [AHR]: 0.53; 95% CI: 0.29-0.97; P = 0.04) and HF hospitalization alone (AHR: 0.40; 95% CI: 0.17-0.95; P = 0.04), among only patients with Vp >20%. The incidence of the primary outcome was highest among RVP with Vp >20% and lowest in CSP with Vp >20% (35% vs 10%, P < 0.001). Compared with RVP with Vp >20%, both CSP with Vp >20% (AHR: 0.51; 95% CI: 0.28-0.91; P = 0.02) and all patients with Vp ≤20% (AHR: 0.73; 95% CI: 0.54-0.99; P = 0.04) were independently associated with reduced primary outcome, driven primarily by reductions in HF hospitalizations (P < 0.05). Event-free survival was similar between CSP with Vp >20% and those needing ≤20% Vp. CONCLUSIONS: CSP significantly reduced adverse clinical outcomes for bradycardic patients requiring ventricular pacing and should be the preferred pacing modality of choice.


Subject(s)
Atrioventricular Block , Cardiac Resynchronization Therapy , Heart Failure , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Bradycardia/therapy , Cardiac Conduction System Disease/therapy , Heart Conduction System , Cardiac Resynchronization Therapy/adverse effects , Atrioventricular Block/therapy , Heart Failure/therapy
10.
J Cardiovasc Electrophysiol ; 33(7): 1550-1557, 2022 07.
Article in English | MEDLINE | ID: mdl-35524417

ABSTRACT

INTRODUCTION: Pacing leads with extendable-retractable helix (EHL) are alternatives to fixed-helix leads (FHL) for conduction system pacing (CSP), but data on handling characteristics are limited. This study evaluated a dual-center experience of lead handling and performance during CSP. METHODS AND RESULTS: Consecutive patients with His-bundle pacing (HBP) or left bundle branch pacing (LBBP) were evaluated for the primary outcome of lead failure, defined as structural damage to the lead necessitating lead replacement. Differences in pacing characteristics were compared. Among 280 patients (mean age 74 ± 11 years, 44% male, 50% LBBP), 246 (88%) received FHL and 34 (12%) received EHL. Of 299 leads used, lead failure occurred more frequently among patients with EHL than FHL (29% vs. 2%, p < .001), regardless of CSP modality. Majority of damaged leads (89%) in the form of helix deformation were successfully removed, with failure occurring in only two patients, both EHL, leading to helix fracture and retention within the septal myocardium. EHL, compared to FHL, was associated with 25-fold increased odds of lead failure (odds ratio: 25.21, 95% confidence interval: 7.35-86.51), and persisted after adjustment in turn for age, pacing modality and indication. CSP implant success rates did not differ by lead design (FHL 80% vs. EHL 71%, p = .18), with similar pacing thresholds at implant and follow-up. CONCLUSION: Helix deformation and fracture were more frequent with EHL in CSP despite similar implant success. These findings have significant implications for lead selection during CSP and raises concerns about the long-term extractability of EHL in CSP.


Subject(s)
Bundle of His , Cardiac Pacing, Artificial , Aged , Aged, 80 and over , Bundle-Branch Block/therapy , Cardiac Conduction System Disease , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Electrocardiography/methods , Female , Humans , Male , Middle Aged , Treatment Outcome
13.
Europace ; 24(4): 606-613, 2022 04 05.
Article in English | MEDLINE | ID: mdl-34849722

ABSTRACT

AIMS: This study aims to determine procedural characteristics, acute success rates, and medium-term outcomes of consecutive patients undergoing His bundle pacing (HBP); and learning curves of experienced electrophysiologists adopting HBP. METHODS AND RESULTS: Consecutive HBP patients at three hospitals were recruited. Clinical characteristics, acute procedural details, and medium-term outcomes were extracted from electronic medical records. Two hundred and thirty-three patients [mean age 74.6 ± 10.1 years, 48% female, 68% narrow QRS, 71% normal left ventricular ejection fraction (LVEF), 55.8% atrioventricular block] underwent HBP. Acute procedural success was 81.1% (mean procedural and fluoroscopic times of 105.5 ± 36.5 and 13.8 ± 9.3 min). Broad QRS was associated with lower HBP success (odds ratio 0.39, P = 0.02). Fluoroscopic and procedural times decreased and plateaued after 30-40 cases per operator. Implant HBP threshold was 1.3 ± 0.7 V at 1.0 ± 0.2 ms and R wave was 5.0 ± 3.9 mV. During follow-up, loss of HBP occurred in a further 12.4% and 11.3% of patients experienced a ≥1 V increase in HBP threshold. Five (2.6%) patients required HBP revision for pacing difficulties. About 8.6% of patients had a >50% decrease in R wave but lead revision for sensing issues was not necessary. On an intention to treat basis, 56.7% of patients in whom HBP was attempted had persisting HBP capture and thresholds of <2 V. CONCLUSION: Physicians adopting HBP should be cognizant of the learning curve and preferentially select non-dependent patients with normal QRS and LVEF, to minimize risk of lead revision. Further rises in HBP threshold may increase battery drain and need for reoperations, important considerations when choosing HBP for cardiac resynchronization therapy.


Subject(s)
Cardiac Resynchronization Therapy , Learning Curve , Aged , Aged, 80 and over , Bundle of His , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Electrocardiography/methods , Female , Humans , Male , Middle Aged , Stroke Volume , Treatment Outcome , Ventricular Function, Left/physiology
14.
J Paediatr Child Health ; 50(3): 196-201, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24373065

ABSTRACT

AIM: Cholangitis is a well-known complication that contributes to morbidity, mortality, as well as health-care utilisation in children with biliary atresia who have undergone the Kasai portoenterostomy. The aim of the study was to determine the common causative organisms for cholangitis and characterise its burden, health-care resource and service utilisation and cost. METHODS: This was a retrospective chart review of children who underwent Kasai portoenterostomy in our institution from 1988 to 2011. The causative organisms were identified based on culture reports. The burden of the disease was estimated based on the number of patients experiencing one or more episodes of cholangitis. Health-care resource and service utilisation were based on different categories, and cost was computed based on the charges at the institution. RESULTS: Twenty-seven (64.3%) out of 42 children included in the analysis experienced at least one episode of cholangitis. There were a total of 97 episodes of cholangitis, with an average of 3.6 (1-15) episodes per patient. The average length of stay per episode of cholangitis was 14.8 (2-64) days. Common organisms isolated during blood cultures were Klebsiella pneumoniae, Enterococcus, Escherichia coli and Pseudomonas aeruginosa. The estimated cost per in-patient admission of 15 days (rounded off) for a single episode of cholangitis was $SG 8986.61 ($US 7369.02). CONCLUSION: The knowledge about the incidence and cost of cholangitis will allow physicians to counsel parents of children newly diagnosed with biliary atresia and to better prepare them both emotionally and financially for what to expect.


Subject(s)
Biliary Atresia/surgery , Cholangitis/economics , Health Resources/statistics & numerical data , Portoenterostomy, Hepatic , Postoperative Complications , Biliary Atresia/complications , Cholangitis/epidemiology , Cholangitis/etiology , Cost of Illness , Female , Health Resources/economics , Humans , Infant , Length of Stay , Male , Medical Audit , Retrospective Studies , Singapore
SELECTION OF CITATIONS
SEARCH DETAIL
...